Exzone Engineering Services

Exzone Engineering Services power & electrical

๐Ÿ”ง ๐…๐ˆ๐‹๐“๐„๐‘๐’ ๐’๐€๐‹๐„ ๐๐Ž๐– ๐Ž๐! ๐Ÿ”งKeep your generators and industrial machines running at peak performance with our premium filter...
12/08/2025

๐Ÿ”ง ๐…๐ˆ๐‹๐“๐„๐‘๐’ ๐’๐€๐‹๐„ ๐๐Ž๐– ๐Ž๐! ๐Ÿ”ง

Keep your generators and industrial machines running at peak performance with our premium filters โ€” now available at special discounted prices!

๐Ÿ› ๏ธ Available Filters:
โœ… Air Filters
โœ… Oil Filters
โœ… Fuel Filters
โœ… Hydraulic Filters

๐Ÿ’ผ Ideal for:
Diesel Generators | Heavy Machinery | Construction Equipment | Industrial Engines

๐Ÿ•’ Limited-time offer โ€“ Donโ€™t miss out!
Ensure longer equipment life, better fuel efficiency, and fewer breakdowns with high-quality filtration solutions.

๐Ÿ“ฆ Bulk orders available | ๐Ÿ“Fast delivery | ๐Ÿ’ฌ Inquire now

๐Ÿ”ง ๐—˜๐—ป๐—ด๐—ถ๐—ป๐—ฒ ๐— ๐—ฎ๐—ท๐—ผ๐—ฟ ๐—ข๐˜ƒ๐—ฒ๐—ฟ๐—ต๐—ฎ๐˜‚๐—น ๐—ฆ๐—ฒ๐—ฟ๐˜ƒ๐—ถ๐—ฐ๐—ฒ๐˜€ โ€“ ๐—ฅ๐—ฒ๐˜€๐˜๐—ผ๐—ฟ๐—ฒ ๐—ฃ๐—ฒ๐—ฎ๐—ธ ๐—ฃ๐—ฒ๐—ฟ๐—ณ๐—ผ๐—ฟ๐—บ๐—ฎ๐—ป๐—ฐ๐—ฒ! ๐Ÿ”งIs your generator engine underperforming or facing repeate...
28/07/2025

๐Ÿ”ง ๐—˜๐—ป๐—ด๐—ถ๐—ป๐—ฒ ๐— ๐—ฎ๐—ท๐—ผ๐—ฟ ๐—ข๐˜ƒ๐—ฒ๐—ฟ๐—ต๐—ฎ๐˜‚๐—น ๐—ฆ๐—ฒ๐—ฟ๐˜ƒ๐—ถ๐—ฐ๐—ฒ๐˜€ โ€“ ๐—ฅ๐—ฒ๐˜€๐˜๐—ผ๐—ฟ๐—ฒ ๐—ฃ๐—ฒ๐—ฎ๐—ธ ๐—ฃ๐—ฒ๐—ฟ๐—ณ๐—ผ๐—ฟ๐—บ๐—ฎ๐—ป๐—ฐ๐—ฒ! ๐Ÿ”ง

Is your generator engine underperforming or facing repeated issues?
We offer complete Engine Major Overhaul services to restore your equipment to like-new condition โ€“ improving efficiency, reliability, and lifespan.
โœ… Inspection & Disassembly
โœ… Replacement of Worn Components
โœ… Precision Reassembly
โœ… Testing & Performance Tuning

๐Ÿ“ž Contact us today to schedule your engine overhaul and reduce costly downtime.

๐Ÿ”‹ ๐—™๐—ข๐—ฅ ๐—ฆ๐—”๐—Ÿ๐—˜: ๐Ÿฎ๐Ÿฐ๐—ฉ๐——๐—– ๐—•๐—ฎ๐˜๐˜๐—ฒ๐—ฟ๐˜† ๐—–๐—ต๐—ฎ๐—ฟ๐—ด๐—ฒ๐—ฟ๐˜€ โ€“ ๐—ฅ๐—ฒ๐—น๐—ถ๐—ฎ๐—ฏ๐—น๐—ฒ ๐—ฃ๐—ผ๐˜„๐—ฒ๐—ฟ ๐—ฌ๐—ผ๐˜‚ ๐—–๐—ฎ๐—ป ๐—ง๐—ฟ๐˜‚๐˜€๐˜! โšกLooking for dependable 24VDC battery chargers for yo...
04/07/2025

๐Ÿ”‹ ๐—™๐—ข๐—ฅ ๐—ฆ๐—”๐—Ÿ๐—˜: ๐Ÿฎ๐Ÿฐ๐—ฉ๐——๐—– ๐—•๐—ฎ๐˜๐˜๐—ฒ๐—ฟ๐˜† ๐—–๐—ต๐—ฎ๐—ฟ๐—ด๐—ฒ๐—ฟ๐˜€ โ€“ ๐—ฅ๐—ฒ๐—น๐—ถ๐—ฎ๐—ฏ๐—น๐—ฒ ๐—ฃ๐—ผ๐˜„๐—ฒ๐—ฟ ๐—ฌ๐—ผ๐˜‚ ๐—–๐—ฎ๐—ป ๐—ง๐—ฟ๐˜‚๐˜€๐˜! โšก

Looking for dependable 24VDC battery chargers for your generators, control panels, or industrial systems?

We offer high-performance 24V battery chargers designed for:

โœ… Diesel & Gas Generator Sets

โœ… Telecom and Control Panels

โœ… Solar & Backup Power Systems

โœ… Industrial and Marine Applications

โœจ Features Include:

Auto 3-stage charging (Bulk / Absorption / Float)

Overload & Short-Circuit Protection

LED/LCD Monitoring

Compact and Durable Design

๐Ÿ“ฆ Available in multiple models and output ranges (5Aโ€“30A)

๐Ÿ’ผ Bulk orders and project supply options available.

๐Ÿ“ž Contact us today for pricing and availability!

๐Ÿ”ง ๐—–๐—”๐—ง ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ ๐— ๐—ฎ๐—ถ๐—ป๐˜๐—ฒ๐—ป๐—ฎ๐—ป๐—ฐ๐—ฒ โš™๏ธEnsure your CAT generator runs at peak performance with our expert maintenance services. โœ…...
03/07/2025

๐Ÿ”ง ๐—–๐—”๐—ง ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ ๐— ๐—ฎ๐—ถ๐—ป๐˜๐—ฒ๐—ป๐—ฎ๐—ป๐—ฐ๐—ฒ โš™๏ธ

Ensure your CAT generator runs at peak performance with our expert maintenance services.

โœ… Oil & filter change

โœ… Battery & coolant check

โœ… Load testing

โœ… Complete system inspection

๐Ÿ“ž Contact us today for reliable support!

๐Ÿ”ง ๐—”๐—ฉ๐—ฅ ๐—œ๐—ป๐˜€๐˜๐—ฎ๐—น๐—น๐—ฎ๐˜๐—ถ๐—ผ๐—ป ๐—ณ๐—ผ๐—ฟ ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ๐˜€ โ€“ ๐—ฃ๐—ฟ๐—ฒ๐—ฐ๐—ถ๐˜€๐—ถ๐—ผ๐—ป ๐—ฉ๐—ผ๐—น๐˜๐—ฎ๐—ด๐—ฒ ๐—–๐—ผ๐—ป๐˜๐—ฟ๐—ผ๐—น โšกInstalling an Automatic Voltage Regulator (AVR) is essent...
02/07/2025

๐Ÿ”ง ๐—”๐—ฉ๐—ฅ ๐—œ๐—ป๐˜€๐˜๐—ฎ๐—น๐—น๐—ฎ๐˜๐—ถ๐—ผ๐—ป ๐—ณ๐—ผ๐—ฟ ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ๐˜€ โ€“ ๐—ฃ๐—ฟ๐—ฒ๐—ฐ๐—ถ๐˜€๐—ถ๐—ผ๐—ป ๐—ฉ๐—ผ๐—น๐˜๐—ฎ๐—ด๐—ฒ ๐—–๐—ผ๐—ป๐˜๐—ฟ๐—ผ๐—น โšก

Installing an Automatic Voltage Regulator (AVR) is essential for maintaining a stable and reliable voltage output from your generator.

โœ… Benefits of Proper AVR Installation:

Protects electrical equipment from voltage spikes

Maintains consistent power under variable load

Enhances generator performance and lifespan

๐Ÿ› ๏ธ Installation Steps:

Power off the generator completely

Locate and remove the old AVR (if present)

Connect the new AVR as per the wiring diagram

Test and calibrate the voltage output

Monitor performance under load conditions

Ensure your generator is ready for any situation with a professionally installed AVR.

๐Ÿ“ž Need AVR support or installation service? Letโ€™s connect!


๐Ÿ”’ ๐—ฆ๐—”๐—™๐—˜๐—ง๐—ฌ ๐—ง๐—œ๐—ฃ๐—ฆ ๐—™๐—ข๐—ฅ ๐—–๐—ข๐— ๐— ๐—˜๐—ฅ๐—–๐—œ๐—”๐—Ÿ ๐—š๐—˜๐—ก๐—˜๐—ฅ๐—”๐—ง๐—ข๐—ฅ๐—ฆ ๐Ÿ”ŒKeeping your generator reliable starts with keeping it safe.Here are key safety...
01/07/2025

๐Ÿ”’ ๐—ฆ๐—”๐—™๐—˜๐—ง๐—ฌ ๐—ง๐—œ๐—ฃ๐—ฆ ๐—™๐—ข๐—ฅ ๐—–๐—ข๐— ๐— ๐—˜๐—ฅ๐—–๐—œ๐—”๐—Ÿ ๐—š๐—˜๐—ก๐—˜๐—ฅ๐—”๐—ง๐—ข๐—ฅ๐—ฆ ๐Ÿ”Œ

Keeping your generator reliable starts with keeping it safe.

Here are key safety practices every commercial generator operator should follow:

โš ๏ธ 1. Regular Maintenance

Prevent breakdowns and hazards with scheduled servicing.

๐ŸŒฌ๏ธ 2. Ensure Proper Ventilation

Install in open or ventilated spaces to avoid carbon monoxide risks.

๐Ÿ”‹ 3. Avoid Overloading

Operate within rated capacity to prevent damage and fire hazards.

๐Ÿงฏ 4. Keep Fire Extinguishers Nearby

Always have Class C extinguishers ready for electrical fires.

๐Ÿ› ๏ธ 5. Secure Fuel Storage

Use approved containers and store fuel safely, away from heat sources.

โšก 6. Professional Installation & Grounding

Ensure expert setup to eliminate electrical risks.

๐Ÿ‘ท 7. Staff Training

Make sure your team is trained in safe operation and emergency response.

Safety is an investment โ€” not an option.

Letโ€™s keep your power running, and your people protected.

๐Ÿ”ง ๐—จ๐—ป๐—ฑ๐—ฒ๐—ฟ๐˜€๐˜๐—ฎ๐—ป๐—ฑ๐—ถ๐—ป๐—ด ๐—ž๐—ฒ๐˜† ๐—ฃ๐—ฎ๐—ฟ๐˜๐˜€ ๐—ผ๐—ณ ๐—ฎ ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ & ๐—ง๐—ต๐—ฒ๐—ถ๐—ฟ ๐—ฃ๐˜‚๐—ฟ๐—ฝ๐—ผ๐˜€๐—ฒ๐˜€ โš™๏ธWhether you're managing power systems or simply interested i...
30/06/2025

๐Ÿ”ง ๐—จ๐—ป๐—ฑ๐—ฒ๐—ฟ๐˜€๐˜๐—ฎ๐—ป๐—ฑ๐—ถ๐—ป๐—ด ๐—ž๐—ฒ๐˜† ๐—ฃ๐—ฎ๐—ฟ๐˜๐˜€ ๐—ผ๐—ณ ๐—ฎ ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ & ๐—ง๐—ต๐—ฒ๐—ถ๐—ฟ ๐—ฃ๐˜‚๐—ฟ๐—ฝ๐—ผ๐˜€๐—ฒ๐˜€ โš™๏ธ

Whether you're managing power systems or simply interested in how generators work, knowing the core components is essential for efficient maintenance and troubleshooting.

Hereโ€™s a quick breakdown:

1๏ธโƒฃ Engine โ€“ The heart of the generator; converts fuel into mechanical energy.

2๏ธโƒฃ Alternator โ€“ Converts mechanical energy into electrical energy.

3๏ธโƒฃ Fuel System โ€“ Stores and supplies fuel to power the engine.

4๏ธโƒฃ Voltage Regulator โ€“ Maintains stable voltage output.

5๏ธโƒฃ Cooling System โ€“ Prevents overheating during continuous use.

6๏ธโƒฃ Exhaust System โ€“ Safely removes harmful engine emissions.

7๏ธโƒฃ Lubrication System โ€“ Reduces friction and extends engine life.

8๏ธโƒฃ Battery โ€“ Powers the generatorโ€™s start-up system.

9๏ธโƒฃ Control Panel โ€“ Monitors and manages generator performance.

๐Ÿ”Ÿ Frame/Base โ€“ Provides support and stability.

๐Ÿ” Circuit Breaker โ€“ Protects against overloads and electrical faults.

๐Ÿ’ก Each component plays a vital role in ensuring reliable and efficient power generation.

๐Ÿ”ง ๐—›๐—ผ๐˜„ ๐˜๐—ผ ๐— ๐—ฎ๐—ธ๐—ฒ ๐—ฌ๐—ผ๐˜‚๐—ฟ ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ ๐—™๐˜‚๐—ฒ๐—น ๐—˜๐—ณ๐—ณ๐—ถ๐—ฐ๐—ถ๐—ฒ๐—ป๐˜?Fuel efficiency is no longer a luxuryโ€”it's a necessity. Whether you're runni...
28/06/2025

๐Ÿ”ง ๐—›๐—ผ๐˜„ ๐˜๐—ผ ๐— ๐—ฎ๐—ธ๐—ฒ ๐—ฌ๐—ผ๐˜‚๐—ฟ ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ ๐—™๐˜‚๐—ฒ๐—น ๐—˜๐—ณ๐—ณ๐—ถ๐—ฐ๐—ถ๐—ฒ๐—ป๐˜?

Fuel efficiency is no longer a luxuryโ€”it's a necessity. Whether you're running a diesel or gas generator, improving fuel efficiency can cut costs and reduce emissions. Hereโ€™s how:

โœ… Maintain Regularly

Keep filters clean, injectors calibrated, and engine tuned to prevent unnecessary fuel burn.

โš™๏ธ Run at Optimal Load

Operating at 70โ€“80% load ensures better fuel-to-power conversion. Avoid long idle times and underloading.

๐ŸŒก๏ธ Monitor Temperature & Cooling

A well-maintained cooling system keeps the engine running efficiently.

๐Ÿง  Upgrade Control Systems

Modern controllers and load-sharing systems reduce fuel waste and enhance performance.

๐Ÿ“Š Right Size Matters

Use a properly sized generator for your application. Oversized units burn more fuel than needed.

๐Ÿ’ก Quality Fuel & Additives

Always use clean, high-grade fuel. Contaminants lower combustion quality and increase consumption.

๐Ÿ’ฌ Are you tracking your generatorโ€™s fuel performance?

Letโ€™s connect and discuss solutions to reduce fuel costs and boost reliability.

๐Ÿ” ๐——๐—ฒ๐˜๐—ผ๐—ป๐—ฎ๐˜๐—ถ๐—ผ๐—ป ๐—ฃ๐—ฟ๐—ผ๐—ฏ๐—น๐—ฒ๐—บ ๐—ถ๐—ป ๐—–๐—”๐—ง ๐—š๐—ฎ๐˜€ ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ โ€“ ๐—–๐—ฎ๐˜‚๐˜€๐—ฒ๐˜€ & ๐—ฆ๐—ผ๐—น๐˜‚๐˜๐—ถ๐—ผ๐—ป๐˜€Facing knocking, high exhaust temps, or shutdowns?๐Ÿ’ฅ Possib...
27/06/2025

๐Ÿ” ๐——๐—ฒ๐˜๐—ผ๐—ป๐—ฎ๐˜๐—ถ๐—ผ๐—ป ๐—ฃ๐—ฟ๐—ผ๐—ฏ๐—น๐—ฒ๐—บ ๐—ถ๐—ป ๐—–๐—”๐—ง ๐—š๐—ฎ๐˜€ ๐—š๐—ฒ๐—ป๐—ฒ๐—ฟ๐—ฎ๐˜๐—ผ๐—ฟ โ€“ ๐—–๐—ฎ๐˜‚๐˜€๐—ฒ๐˜€ & ๐—ฆ๐—ผ๐—น๐˜‚๐˜๐—ถ๐—ผ๐—ป๐˜€

Facing knocking, high exhaust temps, or shutdowns?

๐Ÿ’ฅ Possible Causes:

โ€“ Lean air-fuel mix

โ€“ Wrong ignition timing

โ€“ Poor gas quality

โ€“ Faulty detonation sensor

โœ… We Offer Solutions:

โ€“ Air-fuel & timing adjustment

โ€“ ECM & sensor diagnostics

โ€“ Combustion cleaning

๐Ÿ“ž Prevent engine damage. Get expert service now!

๐Ÿ”ง ๐—ช๐—ต๐—ฎ๐˜ ๐—ถ๐˜€ ๐—ฎ๐—ป ๐—˜๐—ป๐—ด๐—ถ๐—ป๐—ฒ ๐— ๐—ถ๐˜€๐—ณ๐—ถ๐—ฟ๐—ฒ & ๐—›๐—ผ๐˜„ ๐˜๐—ผ ๐—ฆ๐—ฝ๐—ผ๐˜ ๐—œ๐˜? ๐Ÿ”An engine misfire happens when one or more cylinders fail to fire properl...
26/06/2025

๐Ÿ”ง ๐—ช๐—ต๐—ฎ๐˜ ๐—ถ๐˜€ ๐—ฎ๐—ป ๐—˜๐—ป๐—ด๐—ถ๐—ป๐—ฒ ๐— ๐—ถ๐˜€๐—ณ๐—ถ๐—ฟ๐—ฒ & ๐—›๐—ผ๐˜„ ๐˜๐—ผ ๐—ฆ๐—ฝ๐—ผ๐˜ ๐—œ๐˜? ๐Ÿ”

An engine misfire happens when one or more cylinders fail to fire properly, causing rough performance and power loss.

How to spot a misfire:

โœ”๏ธ Rough idling or vibrations

โœ”๏ธ Loss of power

โœ”๏ธ Check Engine Light ON

โœ”๏ธ Poor fuel economy

โœ”๏ธ Unusual engine noise or smoke

Common Causes of Engine Misfire:

๐Ÿ”ง Faulty spark plugs or ignition coils

๐Ÿ’ง Fuel delivery problems (clogged injectors or low fuel pressure)

๐ŸŒฌ๏ธ Vacuum leaks or intake air leaks

๐Ÿงฐ Worn-out engine components (valves, pistons, timing chain)

๐Ÿ” Sensor issues (oxygen sensor, crankshaft/camshaft position sensor)

Don't ignore the signs โ€” early detection prevents bigger engine damage!

Address

Lahore

Opening Hours

Monday 09:00 - 17:00
Tuesday 09:00 - 17:00
Wednesday 09:00 - 17:00
Thursday 09:00 - 17:00
Friday 09:00 - 17:00
Saturday 09:00 - 17:00

Telephone

+923008131011

Alerts

Be the first to know and let us send you an email when Exzone Engineering Services posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Practice

Send a message to Exzone Engineering Services:

Share

Share on Facebook Share on Twitter Share on LinkedIn
Share on Pinterest Share on Reddit Share via Email
Share on WhatsApp Share on Instagram Share on Telegram