Basics of laboratory internal quality control, Ola Elgaddar, 2012 Presentation Transcript

1. Basics of laboratory quality control Ola H. Elgaddar MBChB, MSc, MD, CPHQ Lecturer of Chemical Pathology Medical Research Institute Alexandria University Ola.elgaddar@alex-mri.edu.eg
2. Total Quality Management (TQM) - A continuous approach that seeks to improve quality and performance which will meet or exceed customer expectations. - This can be achieved by integrating all quality-related functions and processes throughout the organization. - TQM requires the involvement of everyone; management, workforce, suppliers, and customers (feedback) - Divided into four sequential categories: plan, do, check, and act
3. In a medical lab, we have threemain stages that need control:1) Pre-analytical2) Analytical3) Post-analyticalAll of them should be under tight control
4. 1) Pre-analytical:• Patient & specimen identification• Patient preparation• Specimen collection, transport and handling• Monitoring personnel
5. 2) Analytical:• Internal quality control (IQC)• External quality assessment (EQA)
6. IQC is used, on daily basis, in the decision toaccept or reject results of patients samplesand enables the lab to describe and monitorthe quality of its work.EQA permits a comparison of quality betweenlaboratories and thus describes the “state ofthe art ” for that area of laboratory workencompassed by the EQA program .It is used to confirm results of IQC
7. 3) Post-analytical:• Transcriptional errors• Unclear report format or information
8. IQC procedures• A stable control material which mimics patient’s sample is analyzed (day to day)• Individual measurements are plotted on a control chart (Levey Jennings charts)• Evaluation whether measurement is “in control” (Westgard multi-rules)
9. Control materialIFCC defines control material as a solutionanalyzed solely for Q.C. purpose and not forcalibrationCriteria to be considered:• 1. Matrix• 2. Reconstitution• 3. Stability• 4. Assayed or un assayed• 5. Appropriate analyte level
10. 1) Matrix:-BASE from which the control material isprepared.-Ideally the same matrix as specimen so thatthey behave like a specimen.- Controls available are HUMAN BASED orBOVINE BASED
11. 2) Reconstitution:• Liquid / lyophilized (Liquid controls better)• Reconstitution material• Quantity of solvent (volume?)• Mixing• Waiting (when to use the reconstituted control)• Vial to vial variation(Standardization of these factors necessary)
12. 3) Stability:• Expiry date and stability after reconstitution should be considered• Desirable is one year supply of the same lot, so that the lab can have its own QC range for a longer period of time.
13. 4) Assayed / Un-assayed QC:• Assayed QC material are the usually used type in our labs• They have manufacturer values for each instrument / method• Those values should be considered as guidelines only till each lab establish its own QC range• Minimum period of time for a lab to establish its own range is 20 days• Ideally, a new QC lot should be run, hand in hand with the old lot, its values are established before it is run routinely.
14. 5) Appropriate analyte level• The used QC material should be covering the measured range of the analyte, both in its normal and pathological range.• It is preferable to have a control value near the medical decision level.• Ideally, there are two levels of QC material used in Chemistry analysis and three levels for hormones and tumor markers.
15. Plotting QC result on Levey Jennings control chart• Mean and SD of QC material (manufacturer or each lab’s values)• Y-axis: control value Vs X-axis: time of run• Most autoanalyzers plot the charts, otherwise they should be drawn manually• A chart is plotted for each control level
16. Evaluating QC results using Westgard rules• Detects whether results are “in control” or not.• Detects the type of laboratory error
17. • Random error, RE, or imprecision is described as an error that can be either positive or negative, whose direction and exact magnitude cannot be predicted, where the distribution of results when replicate measurements are made on a single specimen.• Usually, due to error in pippetting
18. • Systematic error, SE, or inaccuracy is an error that is always in one direction, displacing the mean of the distribution from its original value.• In contrast to random errors, systematic errors are in one direction and cause all the test results to be either high or low.• Either constant or proportionate• Usually, due to error in calibration
19. 1 reading exceeding 2 SD Warning
20. 1 reading exceeding 3 SD Random error Rejection
21. 2 readings exceeding 2 SD Systematic error Rejection
22. 4 readings exceeding 1 SD, on one side of mean Systematic error Rejection
23. 10 readings on the same side of the mean Systematic error Rejection
24. 2 readings, their sum exceeds 4 SD Random error Rejection

15/03/2013

جماعه ترخيص المعامل الخاصه طبعا حولوهو من ادارة المعامل بقى في اداره المؤسسات العلاجيه الخاصه..ديل بيجو يسألو وين السيفتي بوكس وين دفاتر التسجيل والمحاليل دي ليه منتهيه او قربت وبيدققو ودي حاجه كويسه..بس حكاية المسمى. ناس ادارة المعامل السنة الفاتت ادوني اختصاصي في الحتة بتاعت الموهل العلمي..هسه جو الجماعه ديل اول حاجه جابو لينا الاستمارة البنملاها بي طبيب مختبر ومحل اسم طبيب المختبر المسؤول كتبت اسمي طبعا الواحد ابتسم لحدي ما ظهرت سنونو، بعد شوية لمن مشينا وديناها ودفعنا مكتوب المؤهل العلمي تقني مختبرات!!! الحكايه شنو سنة اختصاصي وسنة طبيب مختبر في الاستماره وفي الورق الرمسي المؤهل تقني حيرتونا والله!

11/03/2013

a job offer
here we search for you for an employment inside or outisde Sudan and help you in bien liable to take this offer.. jobs in Saudia, united Arabe emirates and Quatar..and Europe

11/03/2013

welcome our new colleges, I'm sure that we can share befits together s please write the name and the place of work hospital, private clinic, orgnization, or not working..

07/02/2013

مجانا
يعلن مركز أدفانس للتطوير المهني عن قيام محاضرة مجانية مفتوحة يوم السبت 9\2\2013 بعنوان :
Quality Control in Clinical Laboratory Science
- Introduction in QC
- Qualitative QC
- Quantitative QC
- In house QC Calculation
- West Gard rules

يقدمها د\ فيصل التجاني
Lectured by Dr. Faisal E Ibrahim MPA HCM MT(ASCP)

مواعيد المحاضرة الساعه 4:30م - 6:30م

ملحوظة:
*المحاضرات مجانية
*بدون شهادة حضور
*الفرص ((فقط 20 فرصة))

للتسجيل يرجى ارسال رسالة الى الرقم التالي (0125257504) أو عن طريق ارسال رسالة على صندوق اللرسائل في الفيسبوك تحتوي على التالي:-
الاسم , مكان العمل, رقم الهاتف

12/05/2012

welcome to our advanced medical laboratory
all inqueries and questions will be answered and discussed..

Address

Khartoum North

Telephone

00249 9 12419171

Website

Alerts

Be the first to know and let us send you an email when Al Mwasasa Specialized laboratory posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.


Parse error: syntax error, unexpected '}', expecting end of file in /home/multisite/volt/findhealthclinics/%%home%%multisite%%apps%%geosite%%views%%unify01%%partials%%item_sidebar.volt.php on line 287