13/10/2025
We CEMC family proudly presenting The Dräger Atlan A100 Anesthesia machine with ventilator for the first time in Whole Bangladesh. All the supply and Installation done by Our team. Shukriya Alhamdulillah and Thanks to Almighty Allah and also proud of my team.
We CEMC family are sales Channel partner of Dräger under Draeger India Pvt. Ltd. Thanks to Drager Germany and Drager India Pvt Ltd. Also Thanks to DHAKA COMMUNITY MEDICAL COLLEGE for giving us an Opportunity to serve them.
The Dräger Atlan A100 / A100-XL is a modern anaesthesia workstation / breathing-system + ventilator platform designed to be safe, versatile, and efficient. It’s meant for OR use (and supports neonates → adults) with integrated ventilation, gas mixing, monitoring, etc.
Key points of this Machine :
1. Piston Ventilation & Fresh-Gas Decoupling
Uses an electronically driven piston ventilator (E-Vent), which is more precise especially for low tidal volumes, and provides better control even with very small VTs.
Fresh-gas decoupling ensures that changes in fresh gas flows don’t mess up the delivered volume/pressure. This helps maintain stable ventilation even when flow settings change.
2. Low- and Minimal-Flow Anaesthesia with Cost and Environmental Efficiency
The system supports low/minimal fresh-gas flow, integrated warming of breathing system helps reduce condensation (so less waste), efficient gas usage.
“Sample gas recirculated back to the breathing system to eliminate gas loss.”
3. Flexibility / Scalability & Customisation
Available in two trolley sizes (compact and large) (A100 vs A100 XL) to adapt to space constraints.
Options in hardware & software: different patient gas modules, monitor/IV pump mounting positions, media head ceiling supply, etc.
Tailorable user interface; consistent Dräger UI + operating principles reduce the learning curve.
4. Patient Safety & Lung Protective Ventilation
High accuracy even for small tidal volumes; supports adults, paediatrics, neonates.
PEEP maintained even if small leak or during spontaneous breathing; trigger sensitivity is high to detect weak spontaneous effort.
AutoFlow feature to deliver set tidal volume with minimum necessary pressure to avoid overpressure or barotrauma.
5. Hygiene / Infection Control Oriented Design
Breathing system components designed for tool-free disassembly, few parts, many autoclavable or reusable, smooth & rounded external surfaces for cleaning.
Cable channels, minimized clutter so fewer crevices where pathogens accumulate.
6. Connectivity, Digital Support, and Workflow Efficiency
Integration with Dräger Connect and hospital IT systems (HIS, EMR) for data, remote monitoring and maintenance; self-tests, remote diagnostics.
Intuitive workflow features: graphical walkthrough pre-test checklist, automatic self-test, alarm-cause-remedy help functions.
7. Backup / Safety Modes
Backup manual mode in case ventilator / touchscreen / gas mixer fails; ability to continue fresh gas & anaesthetic agent delivery even when machine is off or power supply issues.
In case of central gas supply failure / missing/empty gas cylinders, mechanical ventilation continues with ambient air.
Key Technical Specs at a Glance:
Spec Value / Range
Patient categories supported Neonates, paediatrics, adults
Tidal Volume (VC modes) ~10 mL to 1500 mL
Respiratory Rate (RR) About 3 to 100 breaths/min
I:E ratio (Inspiratory:Expiratory) Approx 1:49 to 49:1
PEEP range Off, 2 to 35 hPa (cm H2O) approx (depends on config)
Peak Inspiratory Flow ~180-220 L/min
Power / Battery backup 100-240 VAC 50/60Hz; less than 95 W during mechanical ventilation (max ~400 W); internal battery backup at least 45 min, typically up to 120 min when fully charged.
Size / Weight Compact trolley ~135 kg; large version ~160 kg; dimensions vary depending on trolley size.
Considerations / Possible Limitations:
As with any high-function workstation, complexity may require training and ongoing support.
To get full functionality (monitor-integration, software options, digital services) hospital IT infrastructure and accessories must be compatible.
Low flow and small volume settings demand accurate calibration/maintenance to ensure performance (gas sensors, valves etc.).
Anesthesia Machine with Ventilator
Brand: Drager Germany
Model: Atlan A100 ( Replacement Model of Fabius Plus)
Origin: Germany