Fixing the rotary prism and Jackson cylinder .. they were not synchronized. Disassemble and lubrication was performed to...
01/22/2024

Fixing the rotary prism and Jackson cylinder .. they were not synchronized. Disassemble and lubrication was performed to ease the inner parts movement and fixing this error.
Calibration was done after assembly of course..

HVK-7000 Auto refractometer printer was not functioning. Replacement for the entire part was done and now it’s working p...
04/26/2023

HVK-7000 Auto refractometer printer was not functioning. Replacement for the entire part was done and now it’s working properly.

Using COVID-19 rest time wisely.😊my painting..
06/21/2020

Using COVID-19 rest time wisely.😊my painting..

04/19/2020

On May 1st at 9 p.m., join us in showing support for Ontario’s doctors! Simply turn on your phone’s flashlight and hold it high. Shine it through your window, on your balcony, on your front porch or wherever you are to show your appreciation for our frontline doctors.

A great gift for my precious clients....🛎🛎- Free diagnosing visit for your clinic- 10% discount on first repair service ...
12/09/2019

A great gift for my precious clients....🛎🛎
- Free diagnosing visit for your clinic
- 10% discount on first repair service
And much more....
For more questions and any concerns please call.

My contact information listed in this page information..
Thanks.

04/11/2019
Tonometer adjustment:Applanation tonometers usually need calibration and lubrication to insure it gives accurate pressur...
02/08/2019

Tonometer adjustment:

Applanation tonometers usually need calibration and lubrication to insure it gives accurate pressure readings.
The picture below illustrates adjustment of tonometer Haag Streit Bern after recording inaccurate readings recently. This process usually is followed by lubrication and recalibration.

Cleaning Slit lamp:As a part of Ophthalmic Equipment preventive maintenance, cleaning and lubrication is necessary to ke...
02/06/2019

Cleaning Slit lamp:

As a part of Ophthalmic Equipment preventive maintenance, cleaning and lubrication is necessary to keep all mechanical parts smooth in motion and to avoid issues that dust could cause it to any Ophthalmic device.

The picture shows Cleaning process to all optical parts(lenses) and mechanical parts for SLIT LAMP CSO.

Projector Cleaning process:Projectors with slides need regular cleaning process. Cleaning projector means disassemble pr...
02/06/2019

Projector Cleaning process:

Projectors with slides need regular cleaning process. Cleaning projector means disassemble projector and cleaning the inner lenses. Calibration and zooming was applied too.

Applanation Tonometer Calibration and adjustment. Service was done in site.
02/04/2019

Applanation Tonometer Calibration and adjustment. Service was done in site.

Phoropter lubrication and cleaning.
02/04/2019

Phoropter lubrication and cleaning.

This is one of repairing service was done on Auto- refractometer HRK 7000. Chin rest automation movement was hanging. Pr...
02/04/2019

This is one of repairing service was done on Auto- refractometer HRK 7000. Chin rest automation movement was hanging. Proper maintenance was performed for it.

02/04/2019

Address

Milton, ON

Opening Hours

Monday 9am - 5pm
Tuesday 9am - 5pm
Wednesday 9am - 5pm
Thursday 9am - 5pm
Friday 9am - 5pm
Saturday 9am - 5pm

Telephone

+1 647-550-6105

Website

Alerts

Be the first to know and let us send you an email when Udjat Ophthalmic Equipment Ltd. posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Practice

Send a message to Udjat Ophthalmic Equipment Ltd.:

Share