Sine Wave

Sine Wave Dental equipment & device store

FARO Italian autoclave Error 110  vacuum failure The sterilization icons are disabled.This is because the current date i...
21/08/2025

FARO Italian autoclave
Error 110 vacuum failure

The sterilization icons are disabled.

This is because the current date is reset after each shutdown of the device, as the memory battery needs to be replaced.

The saved date must exceed the manufacturing date.

Finally cycle complete.

TAU. Clave  3000Alarm 12 Alarm 22Pressure and temperature sensor control faultFinally it's ok
22/07/2025

TAU. Clave 3000
Alarm 12
Alarm 22
Pressure and temperature sensor control fault
Finally it's ok

Preventive maintenance For ACTEON.   Cpct , panorama and ceph Houras radiology center .Helwan
19/07/2025

Preventive maintenance
For ACTEON. Cpct , panorama and ceph

Houras radiology center .Helwan

Button implantation for dental implant motor
14/06/2025

Button implantation for dental implant motor

DOF desktop scanner The problem is that some parts of the model were not fully scanned as shown in the picture "before" ...
14/06/2025

DOF desktop scanner

The problem is that some parts of the model were not fully scanned as shown in the picture "before" due to a weak projector , light source and burnt lenses.

As shown in the picture"after" the problem was resolved by replacing the damaged parts.
And the scan was completed successfully.

Dentsply Sirona Implant motor            Over heated  error  repaired and replace the motor socket  Finally the device w...
22/12/2024

Dentsply Sirona Implant motor
Over heated error
repaired and replace the motor socket
Finally the device works well

CarestreamPano,ceph. Cbct The device has completely stopped workingThe main power supply was damaged as a result of 380 ...
01/08/2024

Carestream
Pano,ceph. Cbct
The device has completely stopped working

The main power supply was damaged as a result of 380 volts entering

Separate 5 volt power supply
Is out of the rang

Finally
The device works well

تابعونا علي قناة اليوتيوب علشان يوصلكوا كل جديد 😍
27/01/2024

تابعونا علي قناة اليوتيوب علشان يوصلكوا كل جديد 😍

Acteon X mind trium Pano ,cbct &ceph Error 76Error 139 Malfunction in the Y stepper motor and its axis repaired and the ...
23/11/2023

Acteon X mind trium
Pano ,cbct &ceph
Error 76
Error 139
Malfunction in the Y stepper motor and its axis
repaired and the device is in good condition

أسرة SINE WAVEتهنئكم بحلول عيد الاضحي اعاده الله علينا و عليكم بالخير واليمن والبركات كل عام و انتم بخير ❤
27/06/2023

أسرة SINE WAVE
تهنئكم بحلول عيد الاضحي اعاده الله علينا و عليكم بالخير واليمن والبركات
كل عام و انتم بخير ❤

Address

نهاية شارع الجيش/برج النبوي/الدور الأول
Mansoura
35511

Telephone

+201004000509

Website

Alerts

Be the first to know and let us send you an email when Sine Wave posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Share

Share on Facebook Share on Twitter Share on LinkedIn
Share on Pinterest Share on Reddit Share via Email
Share on WhatsApp Share on Instagram Share on Telegram

Fengdan

contact us and know more about FENGDAN !