A case of delayed presentation (4.5 weeks), distal biceps rupture.
As distal biceps tendon was heavily scarred, contracted and frayed, PL graft was used.
Endobutton and interference screw used as fixation method at radial tuberosity.
Post op hinge elbow brace with gradual increase of elbow extension each week.