Bonster Ortho

Bonster Ortho Contact information, map and directions, contact form, opening hours, services, ratings, photos, videos and announcements from Bonster Ortho, Medical and health, BONSTER ORTHO PRIVATE LIMITED 55-56-57, silver/1, industrial Estate. opp. HOF furniture. Nr Nova cil petrochemical, Moraiya, Pin/, Ahmedabad.

I am so glad you decided to land on this page, We are R&D people, having secured patents in various critical areas including Orthopedic Implants, Basal Dental Implants, Middle Ear Prosthesis, and Antibiotic Eluting Orthopedic Implants.

18/11/2025

Single-Bicortical Bolt Fixation for Lateral Condyle Fractures: Effective and Minimally Invasive Approach – Dr. Jawahar Jethwa
In many lateral condyle fracture cases, a single screw provides sufficient frictionless fixation, ensuring excellent compression and fragment contact, even in heavy patients. Compared to traditional multi-screw or plate-based methods, this simplified technique offers full range of motion with minimal hardware. In a complex case involving coronal and medial condyle fractures, a combination of MNR-BALT and anteroposterior screws effectively stabilized the site, confirmed via postoperative CT for academic interest. Even with just 2 Bolts, good functional outcomes were achieved.

14/11/2025
Exclusive Offer for Orthopedic Surgeons:Try Before You Buy — Demo Offer! — Absolutely FREE. No Cost. No Risk. No Obligat...
30/10/2025

Exclusive Offer for Orthopedic Surgeons:
Try Before You Buy — Demo Offer! — Absolutely FREE.
No Cost. No Risk. No Obligation to Buy.
Senior surgeon–led planning and guidance available (Paid). Simply share your case.
Trusted Worldwide by Surgeons
Bonster SS & Titanium Orthopedic Implants.
Quality You Can Trust:
✔️ CDSCO, ISO 13485 & CE Certified
✔️ Direct from Manufacturer – Best Prices Guaranteed

Affordable Excellence:
4.5mm Narrow LCP SS - INR. 350
Phillos Locking Plate SS – INR. 1190
3.5mm LH Screw SS – INR. 58
3.5mm T-oblique LCP – INR. 630

Same-day shipping available — Claim your free demo implants now.
We provide worldwide demo shipping at absolutely no cost.

Contact.
+91 821 928 5726
+91 909 922 2195

25/10/2025

1 HOUR MASTERCLASS
Beyond Basics of Basal/Cortical Implantology.
WITH DR. ABHAYDEEP SINGH
dates Date – 26 October, 2025
Time - 12:00 PM
What You’ll Learn:
✔ Basal Implants – Everything You Need to Know
✔ Life-Changing Dental Tips
✔ Q&A Session – Get Your Queries Answered.
At Just ₹999
Register Now

+91 90992 22693 / +91 90992 22891.

PL Dental Implant — Progressive and Strain-Adaptive Loading ProtocolThe PL Implant system applies Frost’s mechanostat, W...
24/10/2025

PL Dental Implant — Progressive and Strain-Adaptive Loading Protocol
The PL Implant system applies Frost’s mechanostat, Wolff’s law, and Perren’s strain theory to harmonize biology and biomechanics. After placement, bone remodeling begins; excessive load may damage healing tissue, while disuse slows regeneration. The Early Progressive Loading (EPL) protocol introduces controlled, stepwise force to maintain strain between 1000–2500 με—ideal for stimulating osteogenesis without overload. Specialized PEEK Healing and Stimulus Caps regulate microstrain and protect tissue during each phase. The implant’s deep threads, conical body, and stable platform ensure high primary stability for early function. Fine-tuned progressive stimulation strengthens bone density, minimizes crestal bone loss, and enhances long-term implant stability. This adaptive approach supports both mid-body anchorage for early loading and basal cortical anchorage for immediate loading, achieving rapid yet biologically safe rehabilitation.
+91 90992 22693
+91 90992 22891

PL Dental Implant — Progressive and Strain-Adaptive Loading ProtocolThe PL Implant system applies Frost’s mechanostat, W...
20/10/2025

PL Dental Implant — Progressive and Strain-Adaptive Loading Protocol
The PL Implant system applies Frost’s mechanostat, Wolff’s law, and Perren’s strain theory to harmonize biology and biomechanics. After placement, bone remodeling begins; excessive load may damage healing tissue, while disuse slows regeneration. The Early Progressive Loading (EPL) protocol introduces controlled, stepwise force to maintain strain between 1000–2500 με—ideal for stimulating osteogenesis without overload. Specialized PEEK Healing and Stimulus Caps regulate microstrain and protect tissue during each phase. The implant’s deep threads, conical body, and stable platform ensure high primary stability for early function. Fine-tuned progressive stimulation strengthens bone density, minimizes crestal bone loss, and enhances long-term implant stability. This adaptive approach supports both mid-body anchorage for early loading and basal cortical anchorage for immediate loading, achieving rapid yet biologically safe rehabilitation.

+91 90992 22693
+91 90992 22891

26/09/2025

quick, affordable, and permanent full-mouth restoration — no bone grafts, no stitches, no waiting. H M Dental Clinic Karnataka & Bonenkar Implants
Experience a quick, affordable, and permanent full-mouth restoration — no bone grafts, no stitches, no long waiting. Using Advanced BYPASS Implant Technology, we give you natural-looking teeth in just 3 days with a high success rate from one-piece implants.
Why Choose Us?
• Expert Implant Care — From single to full-mouth solutions
• Affordable Packages — Transparent and value-driven pricing
• Comfortable Recovery — Peaceful environment in Shiralakoppa, Shimoga District
• Personalized Attention — Experienced professionals with a caring approach
• Optional Ayurveda & Healthy Meals — Support total well-being
Smile confidently, eat comfortably, and speak freely again — thousands have trusted us for painless, lasting transformations.

H M Dental Karnataka & Bypass Dental Implant

06/09/2025

Ahmedabad Bolt: Bicortical Bolt Full Webinar By Dr. Jawahar Jethwa & Bonster Ortho.
The male-female locking mechanism ensures high stability, fatigue resistance, and watertight fixation at the joint surface.
The Ahmedabad Bolt’s male-female interlocking design acts like a self-compressing screw system. When the male component is tightened into the female part, it generates strong axial compression directly across the fracture plane—especially valuable in intra-articular and metaphyseal regions. Ahmedabad bolt holding strength is 250 kg.
This design ensures:
High stability: The bolt locks the fragments firmly, preventing micromovements that can delay healing.
Fatigue resistance: The construct withstands repetitive loading during early mobilization without loosening or failure—even under full weight-bearing.
Watertight fixation: The tight interdigitation of components compresses the joint interface, sealing off the synovial cavity and reducing the risk of fluid ingress, which is known to impair healing.
In essence, it behaves like an internal clamp, offering both mechanical integrity and biological advantages at the joint surface.

Address

BONSTER ORTHO PRIVATE LIMITED 55-56-57, Silver/1, Industrial Estate. Opp. HOF Furniture. Nr Nova Cil Petrochemical, Moraiya, Pin/
Ahmedabad
382213

Alerts

Be the first to know and let us send you an email when Bonster Ortho posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Contact The Practice

Send a message to Bonster Ortho:

Share

Share on Facebook Share on Twitter Share on LinkedIn
Share on Pinterest Share on Reddit Share via Email
Share on WhatsApp Share on Instagram Share on Telegram